Sign In | Join Free | My burrillandco.com
Home > Low Voltage Power Cable >

Heat Resistant Flexible Cable , 0.6-1kV WDZAN-YJY/N2XY Single Core Cable

SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Heat Resistant Flexible Cable , 0.6-1kV WDZAN-YJY/N2XY Single Core Cable from wholesalers
     
    Buy cheap Heat Resistant Flexible Cable , 0.6-1kV WDZAN-YJY/N2XY Single Core Cable from wholesalers
    • Buy cheap Heat Resistant Flexible Cable , 0.6-1kV WDZAN-YJY/N2XY Single Core Cable from wholesalers
    • Buy cheap Heat Resistant Flexible Cable , 0.6-1kV WDZAN-YJY/N2XY Single Core Cable from wholesalers

    Heat Resistant Flexible Cable , 0.6-1kV WDZAN-YJY/N2XY Single Core Cable

    Ask Lasest Price
    Brand Name : DONGJIAXIN
    Model Number : WDZBN-YJY
    Certification : IEC 60502-1
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    Supply Ability : 100KM/WEEK
    Delivery Time : 7-15 working days
    • Product Details
    • Company Profile

    Heat Resistant Flexible Cable , 0.6-1kV WDZAN-YJY/N2XY Single Core Cable

    Cylinder High Temperature Resistance Wdzan-yjy Low Voltage Cable


    Product Description:

    Copper Conductor XLPE Insulation and LSZH Jacket Flame retatent Power Cable

    ▼ Application:

    1kV for Fixed installations such as distribution networks or industrial installations.

    ▼ Constraction:

    Core Conductorannealed copper (stranded core)
    Popular sizes2~5 core x1.5~630mm²
    Cable conductorstranded annealed copper
    InsulationXLPE
    JacketLSZH
    Temperature rating-25C up to +90℃
    Voltage suitable0.6/1kV
    Flame LevelIEC 60332-3-23
    ApprovalQS in China

    ▼Advantage:

    Heat resistance:

    XLPE with a three-dimensional network structure has excellent heat resistance. It will not decompose and carbonize below 200℃, the long-term working temperature can reach 90℃, and the thermal life can reach 40 years;
    Insulation performance:

    XLPE maintains the original good insulation properties of PE, and the insulation resistance is further increased. The dielectric loss tangent value is very small, and it is not greatly affected by temperature.
    Mechanical properties:

    Due to the establishment of new chemical bonds between macromolecules, the hardness, stiffness, wear resistance and impact resistance of XLPE have been improved, thereby making up for the shortcomings of PE being vulnerable to environmental stress and cracking.
    Chemical resistance:

    XLPE has strong acid and alkali resistance and oil resistance. Its combustion products are mainly water and carbon dioxide, which are less harmful to the environment and meet the requirements of modern fire safety.

    ▼ Standards Certificates:

    IEC 60502-1

    ▼Technical parameters:

    1. Single Core

    Cross section of conductor(mm²)Conductor structureInsulation Thickness(mm)Copper sheath thickness(mm)Approx.cable diameter(mm)Max resistance of conductor at 20℃ (Ω/km)
    1×70141.11.415.10.268
    1×95191.11.517.30.193
    1×120241.21.519.00.153
    1×150301.41.620.90.124
    1×185371.6

    1.6

    23.00.0991
    1×240481.71.725.70.0754
    1×300611.81.828.30.0601

    2. 2 Core&3 Core

    Cross section of conductor(mm²)Conductor structureInsulation Thickness(mm)Copper sheath thickness(mm)Approx.cable diameter(mm)Max resistance of conductor at 20℃ (Ω/km)
    2×610.71.813.23.08
    2×1070.71.815.41.83
    2×1670.71.817.41.15
    2×2570.91.820.60.727
    2×3570.91.822.60.524
    2×50101.01.826.20.387
    2×70141.11.829.80.268
    2×95191.11.934.00.193
    2×120241.22.037.40.153
    2×150301.42.241.20.124
    2×185371.62.345.60.0991
    2×240481.72.551.00.0754
    2×300611.82.656.00.0601
    3×610.71.814.03.08
    3×1070.71.816.41.83
    3×1670.71.818.61.15
    3×2570.91.822.00.727
    3×3570.91.824.20.524
    3×50101.01.828.00.387
    3×70141.11.932.10.268
    3×95191.12.036.40.193
    3×120241.22.140.30.153
    3×150301.42.344.30.124
    3×185371.62.449.10.0991
    3×240481.72.654.90.0754
    3×300611.82.760.10.0601

    Company information:

    30 years of experience in R&D, production, and sales of wire and cable.

    Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

    Annual revenue is about 500 million US dollars.

    CNAS laboratory, more than 100 testing reports.

    Products are widely used in real estate, municipal, industrial support, mobile communications etc

    Heat Resistant Flexible Cable , 0.6-1kV WDZAN-YJY/N2XY Single Core Cable


    Heat Resistant Flexible Cable , 0.6-1kV WDZAN-YJY/N2XY Single Core Cable
    Payment:

    We usually use T/T

    T/T deposit before production and balance when shipment.

    Payment terms: Western Union, Escrow, Paypal, T/T, L/C

    Shipping:

    For big orders, we will ship the goods by air or by sea.

    ss section of conductor(mm²)Conductor structure(mm)Insulation thickness(mm)Approx. cable diameter(mm)Max resistance of conductor at 20℃ (Ω/km)
    0.516/0.190.62.1±0.139.0
    0.7524/0.190.62.3±0.126.0
    132/0.190.62.5±0.119.5
    Quality Heat Resistant Flexible Cable , 0.6-1kV WDZAN-YJY/N2XY Single Core Cable for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)